GRASEBY 3300 SYRINGE DRIVER

Introduction No more bulky batteries, just one sleek unit More information. Parameters and options Table 2. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. Quick Guider After getting this alarm system, you need to do the following. The customer may reset the thrust for their own particular requirement. To avoid syphoning of the syringe contents free flow , ensure that the syringe is correctly loaded into the pump, that the syringe plunger is properly engaged by the pump s actuator and that the pump is placed not more than 80cm above the infusion site.

Uploader: Nek
Date Added: 20 July 2016
File Size: 8.12 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 27089
Price: Free* [*Free Regsitration Required]

Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA programmable switch outputs Hysteresis.

The drive system is designed so that it is only engaged when the top of the syringe is correctly positioned in the plunger clamp. Will usually dispatch within 2 working days of receiving cleared payment – opens in a new window or tab.

Alternatively, if a syringe is not fitted or a syringe smaller than 20 ml is fitted, then neither sensor will be de-activated and the syringe grzseby alarm will be given. The model pump is being used world wide for a varietyof strong and weak analgesics for both adults and children.

” + heading + “

Quick Guider After getting this alarm system, you need to do the following More information. As Q1 turns off the voltage across switching inductor L1 charges C3 via flyback diode D2.

  HP SMART ARRAY B110I SATA RAID DRIVER

T ma for a V AC supply. Errors and omissions excepted. This was a basic syringe pump capable of infusions within the range of 0. Under-delivery of medication can cause complications resulting in patient injury or death. The internal pump batteries must be disposed of in accordance with the manufacturers instructions. syrinnge

All programmed values are retained following power off or AC failure. May not post to United States – Read item description or contact seller for postage options.

Used GRASEBY programable Pump PCA For Sale – DOTmed Listing #

Place the weight support rod through the modified 60 ml syringe and onto the pump’s plunger clamp. The PCAS was very similar to the MS in both appearance and mechanical design, but utilised a different microprocessor with the capability of running the extra features required for PCA and was eventually replaced by the pump. The device must be used to administer only those analgesics which are approved for epidural administration as indicated by the drug labelling.

Data from the switch panel is delivered to IC16 on pins 32, 33, and When the label is positioned correctly into the case recess i. Potentiometer RV1 is set as follows: The super nut assembly pulls the outer of two steel tubes to the left. Sellers set the item’s declared value and must comply with customs declaration laws. Manuel d installation Installation manual. 3300 additional information, see the Global Shipping Programme syrings and conditions – opens in a new window or tab This amount includes applicable customs duties, taxes, brokerage and other fees.

  920C DESKJET DRIVER DOWNLOAD

Skip to main content.

Page viii Issue 7 August Service Manual. Programmable 9 x 32 digit phone numbers for each trigger. This document may not be copied or reproduced in whole or in part, or transferred to any. Lever the two sides of the super nut apart in order to disengage the casting pip from the locating hole in the metal tube.

Infusion Devices

To use this website, you must agree to our Privacy Policyincluding cookie policy. Failure to observe this warning may cause damage to the PCA pump and harm the operator or the patient.

Select a valid country. As with any instrument of this type it should be bio-med certified before use in a medical environment. Take care not to bend the new panel, and carefully handle the flexible cable loom.

Delivery Policy We deliver medical and dental equipment globally, insured and tracked as standard using trusted couriers. If the pump is used in the presence of, or in combination with Magnetic Resonance Imaging MRI machines it must be protected from the magnetic field emitted by such equipment.